Nanhua Instruments | National High-tech Enterprise

+
  • _DSC7809.png
  • _DSC7818.png

NHVOC-1(P) Portable VOCs Monitor (OID-NDIR)

NHVOC-1 (P) Portable VOC Monitor adopts both NDIR and PID principles to measure the amount of TVOC in the detecting gases.

Classification:

Product Center

Environmental Monitoring

Portable VOCs Monitor

Product Documentation:

Monitoring principle:
PID-NDIR

Details

Based on the combined measurement principles of PID (Photoionization Detection) and Non-Dispersive Infrared Absorption (NDIR), this system is suitable for VOCs source tracing, rapid detection of purification efficiency in treatment facilities, organized and unorganized on-site emergency detection for enterprises, and pipeline emission leakage detection in chemical plants.


Features

  • The monitoring method complies with the requirements of DB44/T1947-2016 and US EPA Method 25B, ensuring stable and highly reliable technology.
  • Simple and convenient dual-button operation with ultra-short detection time, enabling rapid and continuous on-site monitoring.
  • Dual detectors offer a wide measurement range, excellent and stable sensitivity to most monitoring gases, and strong applicability.
  • Compact design with lightweight components and composite materials, making the device small and light for easy portability.
  • Built-in polymer lithium-ion rechargeable battery eliminates the need for an external power supply, allowing the instrument to be preheated for quick on-site measurements.

Applications

Applicable to VOCs source tracing, rapid detection of purification efficiency in treatment facilities, organized and unorganized on-site emergency detection for enterprises, and pipeline emission leakage detection in chemical plants.


Specifications

NHVOC-1(P)

Operating Condition

Ambient Temp.

+5ºC~+40ºC

Relative Humidity

5%~95% (Non-Condensing)

Atmosphere Pressure

70 kPa~106 kPa

Power Supply

Voltage

DC12V (built-in lithium 5600mAh)

Measuring Range

TVOC

(0~200) x10-6 vol

Resolution

TVOC

1 x10-6 vol

Allowable Indication Error

Absolute Error

Relative Error

TVOC

±4 x10-6 vol

±3%

Measuring Method

Extractive

Insert the probe into the emission pipeline to directly extract gas sample .

Time Stability

After warm-up, zero drift and range drift do not exceed allowable error for 4h.

Warm-up

15 min (ambient temp.not less than 20ºC)

Others

Output Interface

WIFI Communication (optional)

Bluetooth Printer (optional)

Dimension (L×W×H)

885×120×185mm

Weight

5kg


Download

2024-07-12

Related Products

Online Message


Pre-sales After-sales

Model:

Submit

Model:

Submit
Picture Name

Nanhua Instruments Co., Ltd.

Add: 1 Kehong, Rd., Guicheng, Nanhai District, Foshan City, Guangdong 528251 CHINA
Tel: +86 757 86718778
Export Dept.
Tel: +86 757 86718629
Email: Export@nanhua.com.cn

Online Message

Pre-sales After-sales

Model:

Submit

Model:

Submit
Picture Name

Nanhua Instruments Co., Ltd.

Add: 1 Kehong, Rd., Guicheng, Nanhai District, Foshan City, Guangdong 528251 CHINA
Tel: +86 757 86718778
Export Dept.
Tel: +86 757 86718629
Email: Export@nanhua.com

Online Message

Pre-sales After-sales

Model:

Submit

Model:

Submit