+
  • NHA-506.jpg

NHA-406/506 Gas Analyzer

To measure the concentrations of HC, CO, CO2, O2 and NO, and λ of the exhaust gas from motor vehicles.

Classification:

Product Center

Vehicle Inspection

Gas Analyzer

Product Documentation:

Measuring Range:
HC: 0~9,999×10-6 (hexane equivalent)
CO: 0~10×10-2 (%)
CO2: 0~18×10-2 (%)
O2: 0~25×10-2 (%)
NO: 0~5,000×10-6 (only NHA-506)

Details

The analyzer adopts the NDIR principle to measure the content of CO, HC and CO2, and the electrochemistry principle to measure the content of NO and O2 in the exhaust smoke from the gasoline engine, and finally obtain the excess air coefficient λ based on the content of CO, CO2, HC and O2. Capable of performing multi-mode dual-speed idle test on gasoline, natural gas (LNG/CNG), liquefied petroleum gas (LPG), ethanol gasoline, and various fuel-powered vehicles.

 

 

Options
  • Micro Thermal Printer
  • Engine Oil Temp. Probe
  • RPM speed counter of various models
  • Vehicle power inverter

Features

  • Able to inspect vehicle of various fuels such as CNG, LPG and ethanol gasoline.
  • LED operation screen, allowing to input license no. and save 200 sets data.
  • Standard configuration includes inductive RPM tool and RS-232 digital communication interface.
  • Standard preheat time of 10 min, with a quick preheat option of 5 min to meet emergency testing needs.
  • Conform to ISO3930 and OIMLR99 Class I Precision.

Applications

Applicable to environmental protection departments, vehicle inspection and detection station, vehicle manufacturers, mobile exhaust gas inspection station, etc.


Specifications

 

NHA-406

NHA-506

Measuring Range

HC

0~9,999×10-6 (hexane equivalent)

CO

0~10×10-2 (%)

CO2

0~18×10-2 (%)

O2

0~25×10-2 (%)

NO

NA

0~5,000×10-6

Indication Error

HC

0~2,000×10-6:

Absolute Error: ±12×10-6 (%)

Relative Error: ±5×10-2 (%)

*Whichever is greater

2,001~9,999×10-6:

Relative Error: ±10×10-2 (%)

CO

Absolute Error: ±0.06×10-2 (%)

Relative Error: ±5×10-2 (%)

*Whichever is greater

CO2

Absolute Error: ±0.5×10-2 (%)

Relative Error: ±5×10-2 (%)

*Whichever is greater

O2

Absolute Error: ±0.1×10-2 (%)

Relative Error: ±5×10-2 (%)

*Whichever is greater

NO

NA

Absolute Error: ±25× 10-6

Relative Error: ±4×10-2 (%)

Response Time

≤ 10s, O2 ≤ 12s

≤ 10s, O2 ≤ 12s, NO ≤ 15s

Warm-up Time

10 min (ambient temp.not less than 20℃)

Power Supply

AC220V±10% 50Hz±1Hz or DC12V (optional vehicle power inverter available)

Weight

6 kg

Dimension

260×180×450mm (W×H×D)


Online Message


Pre-sales After-sales

Model:

Submit

Model:

Submit
Picture Name

Nanhua Instruments Co., Ltd.

Add: 1 Kehong, Rd., Guicheng, Nanhai District, Foshan City, Guangdong 528251 CHINA
Tel: +86 757 86718778
Export Dept.
Tel: +86 757 86718629
Email: Export@nanhua.com

Online Message

Pre-sales After-sales

Model:

Submit

Model:

Submit
Picture Name

Nanhua Instruments Co., Ltd.

Add: 1 Kehong, Rd., Guicheng, Nanhai District, Foshan City, Guangdong 528251 CHINA
Tel: +86 757 86718778
Export Dept.
Tel: +86 757 86718629
Email: Export@nanhua.com

Online Message

Pre-sales After-sales

Model:

Submit

Model:

Submit